PUMP ORDERING * | ||||||||
Sample order: | IFP | VTM42 | 40 | 15 | 20 | NO | R | K |
Legend | (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) |
(1) | IFP – single units | |||||||
(2) | VTM42 – power steering | |||||||
(3) | 40 – ring size (see specification below) | |||||||
(4) | 15 – controlled flow (see Table A below) | |||||||
(5) | 20 – relief setting (see Table B below) | |||||||
(6) | NO – w/o tank, T – tank, M – manifold | |||||||
(7) | R – clockwise, L – counterclockwise | |||||||
(8) | K – threaded keyed shaft | |||||||
* Parts and mounting interchangeable with Vickers. |
PUMP OPERATING SPECIFICATIONS Based on using petroleum oil at 120 F (49 C), viscosity 150 SUS at 100 F (32 cSt at 38 C), and 0 psi inlet pressure |
|||||||
IFP Model series | Ring size Delivery USgpm @ 1200 r/min & 100 psi |
Displ. in3/r (cm3/r) |
Maximum speed – r / min | Maximum pressure psi (bar) |
Weight lb (kg) |
||
100 psi @7 bar | 1500 psi @100 bar | 2000 psi @140 bar | |||||
VTM42 | 1 1.5 2 4 5 6 |
0.21 (03,4) 0.31 (05,1) 0.38 (06,2) 0.79 (12,9) 0.96 (15,7) 1.18 (19,3) |
7000 7000 7000 7000 6000 5000 |
5000 4500 4200 2800 2600 2500 |
4250 4000 3800 2800 2300 2000 |
2000 (140) | 14 (6,4) |
Parts and mounting interchangeable with Vickers.
Table A — CONTROLLED FLOW @ 1500 rpm & 100 psi (7 bar) |
||
15 | 1.5 USgpm | (6 L/min) |
20 | 2 USgpm | (8 L/min) |
25 | 2.5 USgpm | (9,5 L/min) |
30 | 3 USgpm | (11 L/min) |
35 | 3.5 USgpm | (13 L/min) |
40 | 4 USgpm | (15 L/min) |
45 | 4.5 USgpm | (17 L/min) |
50 | 5 USgpm | (l9L/min) |
55 | 5.5 USgpm | (21 L/min) |
60 | 6 USgpm | (23 L/min) |
65 | 6.5 USgpm | (25 L/min) |
70 | 7 USgpm | (26,5 Llmin) |
75 | 7.5 USgpm | (28 L/min) |
Table B — RELIEF SETTING | ||
05 | 500 psi | (35 bar) |
07 | 750 psi | (52 bar) |
10 | 1000 psi | (70 bar) |
12 | 1250 psi | (86 bar) |
15 | 1500 psi | (100 bar) |
17 | 1750 psi | (120 bar) |
20 | 2000 psi | (140 bar) |